MOTS-c vs SS-31: two mitochondrial research peptides on paper

Two peptides that appear together in mitochondrial research and have almost nothing in common chemically. This page compares them strictly as analytical objects: sequence, formula, theoretical mass, the impurity each sequence predicts, and what a certificate of analysis for each has to show.

Research-use scope. This page describes laboratory research materials and their analytical documentation. It is not for use in people or animals, contains no handling, preparation, or procedural guidance, and makes no claim that any material named here is safe or effective for any purpose. It compares identity and documentation only; it does not compare, rank, or recommend the materials for any application.

Sixteen natural residues against four modified ones

MOTS-c is a 16-residue peptide whose sequence is encoded within the 12S rRNA region of the mitochondrial genome; the material supplied for laboratory work is made by solid-phase synthesis. SS-31, also called elamipretide, is a synthetic tetrapeptide from the Szeto-Schiller series, built from alternating basic and aromatic residues, two of them non-standard. The figures below are the ones published on the MOTS-c 10mg, MOTS-c 40mg and SS-31 10mg listings, with the expected ions calculated from those formulas.

PropertyMOTS-cSS-31 (elamipretide)
SequenceMRWQEMGYIFYPRKLRD-Arg-Dmt-Lys-Phe-NH2 (Dmt = 2,6-dimethyltyrosine)
Residue count164
TerminiFree amine, free acidFree amine; C-terminal amide
Non-standard residuesNoneD-arginine; 2,6-dimethyltyrosine
Molecular formulaC101H152N28O22S2C32H49N9O5
CAS registry number1627580-64-6736992-21-5
Theoretical average mass2,174.6 g/mol639.8 g/mol
Theoretical monoisotopic massapproximately 2,173.1approximately 639.4
Ions a mass spectrum typically showsMultiply charged: near m/z 1,087.6 (2+), 725.4 (3+), 544.3 (4+)near m/z 640.4 (1+) and 320.7 (2+)
Oxidation-prone residuesMethionine at 1 and 6, tryptophan at 3None (no methionine, cysteine or tryptophan)
Sulfur in the formulaTwoNone
Physical form suppliedLyophilized solidLyophilized solid

The masses above are calculated from the formulas on the listings; read them as orientation. The report for a specific lot is the authoritative record, and where it disagrees with this page, the report governs.

MOTS-c: oxidation is the line to read

SS-31: the error a mass result cannot see

What each certificate of analysis must show

Report sectionFor a MOTS-c lotFor a SS-31 lot
IdentityMass in agreement with 2,174.6 g/mol (monoisotopic near 2,173.1) within tolerance, with the charge states listed or the deconvoluted mass stated, or HPLC-RTM against a named MOTS-c reference standardMass in agreement with 639.8 g/mol (monoisotopic near 639.4) within tolerance, or HPLC-RTM against a named SS-31 reference standard; the D-residue is only confirmed by the chromatographic result
Chromatographic purityMain-peak area as a percentage of total integrated area, with the chromatogram published; check the early side of the main peak for oxidised species (+16, +32)The same figure and trace; check peak shape for tailing and for a near-eluting diastereomer peak
Net contentMeasured mg of peptide in the vial, stated next to the labeled strengthMeasured mg of peptide in the vial, stated next to the labeled strength
EndotoxinWhere tested: the method (LAL, with the USP <85> reference if claimed), the result with its units (EU per mL, per mg or per vial), and the limit it was compared against.
Heavy metalsWhere tested: the elements in the panel, the method, and a result or "none detected" against a stated reporting limit.
Method fieldsColumn, mobile phase or gradient, detection wavelength, and reporting limit. A percentage with no method attached is not a result.
Record fieldsMaterial name, labeled strength, lot identifier matching the vial label, test date, certificate or accession number, and the issuing laboratory with its verification route.

Endotoxin and heavy-metal screens are only part of a report when the laboratory ran them. If a line is not on the certificate, that test was not performed on that lot; it has not been passed. The endotoxin testing guide explains what a LAL result and a USP <85> pass mean, and net peptide content explains why the measured mg can differ from the label.

How to tell them apart on paper

  1. Find the stated mass. Near 2,175 is MOTS-c; near 640 is SS-31.
  2. Look for sulfur in the formula. MOTS-c contains two S atoms; SS-31 contains none.
  3. Read the ion list. A MOTS-c report shows a family of multiply charged ions; an SS-31 report shows a singly charged ion near m/z 640.
  4. Check the strength on the record. A 10 mg lot report does not describe a 40 mg vial, even for the same compound.

How to read our reports for these two

Our current reports come from three laboratories. Freedom Diagnostics reports give purity by HPLC-UV, identity by LC-MS, net content in mg, and an endotoxin result where one is listed; each carries an accession number and a search code for the laboratory's lookup page. ILS Laboratories reports give purity by HPLC, identity by retention-time match against a reference standard, net peptide content, and the screens run on that lot. Janoshik Analytical reports carry the laboratory's own verification key. Verify a lab report walks through each lookup.

On Arctic Lab Supply reports. Every currently published report is listed in the batch COA library with its certificate or accession number and verification link. The report for the lot you receive is the one that governs; where an earlier lot's figures differ, the lot-specific report is authoritative.

Common questions

How do MOTS-c and SS-31 differ on a certificate of analysis?

MOTS-c is a 16-residue peptide, MRWQEMGYIFYPRKLR, C101H152N28O22S2, 2,174.6 g/mol. SS-31 is the tetrapeptide D-Arg-Dmt-Lys-Phe-NH2, C32H49N9O5, 639.8 g/mol. Their masses, sulfur content and ion patterns are all different, so a report for one cannot describe the other.

What mass should each report state?

MOTS-c: about 2,173.1 (monoisotopic) or 2,174.6 g/mol (average), usually seen as ions near m/z 1,087.6, 725.4 and 544.3. SS-31: about 639.4 (monoisotopic) or 639.8 g/mol (average), near m/z 640.4 and 320.7.

What impurity does each sequence predict?

MOTS-c has two methionines and a tryptophan, so oxidised species 16 or 32 units heavier, eluting just before the main peak, are the expected impurity. SS-31 has no oxidation-prone residue; the error to rule out is a wrong D/L isomer, which has the same mass and is caught by the chromatogram.

Which MOTS-c and SS-31 lots are documented on this site?

MOTS-c 10mg lot MOTS-2510-A has a published Freedom Diagnostics report (99.64% by HPLC-UV, LC-MS identity, net content 11.50 mg, endotoxin pass, Nov 1, 2026). MOTS-c 40mg and SS-31 10mg were listed in November 2026; their lot reports are posted on the product pages and in the COA library when they are back.

Related documentation